Abstract:
The study proposes a method of electrical lighting calculation for a road tunnel, which allows estimating locations of selected luminaires providing the required road surface luminance distribution in the areas of vehicle driver adaptation while driving through a tunnel during daytime. The method is based on the adopted concepts of saturation curve and luminance saturation zone which are used for building of a step curve approximating the set zonal distribution of luminance. The basic terms of the method and the calculation algorithm as well as an example of calculation of luminaire locations in the tunnel luminance zones illustrated by comparison of estimated and pre-set luminance distributions are presented.
References:
1. CIE88–2004: Guide for the lighting of road tunnels and underpasses. 2. Standard, GOST R56334–2015 Road tunnels. Artificial lighting. Norms and design methods. 3. Standard, GOST R55708–2013 Road lighting. Design methods of normative performances 4. Korobko, A.A. Utilitarian Outdoor Lighting: A Study Guide for Universities [Utilitarnoye naruzhnoye osveshcheniye: Uchebnoye posobiye dlya vysshykh uchebnykh zavedeniy] / Moscow: Svetotekhnika / Light & Engineering Journal Editorial Board, 2020, 124 p.