Content
Abstract:
1In lighting design, the main concept is to achieve a healthy environment, which addresses energy efficiency, cost, maintenance, and quality. User-friendly lighting systems shall be adopted to architecture and interior architecture. User control over the lighting system is important, by dimming or increasing light output, by changing the colour of the light sets the inner atmosphere and affects user mood. Standards and codes on lighting shall also be evaluated by means of these topics. The paper aims to analyse how the luminous environment is affective on the perceived environment. Hence, a series of experimental studies and recent research will be evaluated in regard to understanding and designing luminous environment.
References:
1. Boyce P.R. Human factors in lighting, 2nd Ed. Lighting Research Center // Taylor and Francis, London, 2003, 602 p. 2. European Committee for Standardization. Light and lighting, lighting of work places. Part 1. EN12464-1. Brussels: Indoor Work Places; 2004. 3. van den Beld, van Bommel. Lighting for work: visual and biological effects // Lighting Research and Technology, 2004. DOI:10.1191/1365782804li122oa 4. Flynn J.E., Hendrick C., Spencer T., Martynuik O. Interim Study of Procedures for Investigating the effect of Light on Impression and Behavior // Journal of Illuminating Engineering Society, 1973, No. 3, pp. 87-94. 5. Flynn J.E., Hendrick C., Spencer T., Martynuik O. A Quide to Methodology Procedures for Measuring Subjective Impressions in Lighting // Journal of Illuminating Engineering Society, 1979, No. 8, pp. 95-110. 6. Hawkes R., Loe D., Rowlands E. A Note Towards the Understanding of Lighting Quality // Journal of Illuminating Engineering Society, 1979, No. 8, pp. 111-120. 7. Manav B., Yener C. Effects of different lighting arrangements on space perception // Architectural Science Review, 1999, Vol. 42, No. 1, pp. 43-47. 8. Manav B. An experimental study on the appraisal of the visual environment at offices in relation to colour temperature and illuminance // Building and Environment, 2007, Vol. 42, No. 2, pp. 979-983. 9. Ashdown I., The Kruithof Curve: A Pleasing Solution, Research Gate. URL: www.agi32.com/ blog-2015/01/12 10. Manav B., Erkin E., Guler O., Onaygil S. An experimental study on tubular fluorescent and LED lamps with respect to energy performance and visual comfort // Light and Engineering, 2013, Vol. 21, No. 4, pp. 50-57. 11. Fotios S. A Revised Kruithof Graph Based on Empirical Data // Leukos, Vol. 13, No. 1, pp. 3-17. DOI:10.1 080/15502724.2016.1159137. 12. Knez I. Effects of Colour of Light on nonvisual psychological processes // Journal of Environmental Psychology, 2001, Vol. 21, pp. 201-208. 13. Veitch J.A., Newsham G.R. Lighting quality and energy-efficient effects on task performance, mood, health, satisfaction and comfort // Journal of the Illuminating Engineering Society, 1998, Vol. 27, No. 1, pp. 107-130. 14. Huiberts L.M., Smolders K.C.H.J., de Kort Y.A.W. Shining light on memory: effects of bright light on working memory performance // Behavioural Brain Research, 2015, Vol. 294, pp. 234-245. 15. Dai Q., Cai W., Shi W., Hao L., Wei M. A proposed lighting-design space: Circadian effect versus illuminance // Building and Environment, 2017, Vol. 122, pp. 287-293. 16. Bellia L., Bisegna F., Spada G. Lighting indoor environment: visual and non-visual light sources with different spectral power distribution // Building and Environment, 2011, Vol. 46, pp. 1984-1992. 17. CIE205:2013 Review of lighting quality measures for interior lighting with LED lighting systems. 18. Brainard G.C. Photoreception for regulation of melatonin and the circadian system in humans // Fifth International LRO lighting research symposium, Orlando, 2002. 19. Figueiro M., Gonzales K., Pedler D. Designing with circadian stimulus // LD+A, 2016, pp. 31-34. 20. Figuera et al. Lighting for visual performance, circadian health and safety in older adults, webinar, Philips Lighting University, 25.01.2018. 21. American National Standard Practice for Office Lighting, Office Lighting Committe of the ESNA, ANSI / IESNA RP-1, 1993. 22. CIBSE, Code for interior lighting, The Chartered Engineers, London, 1984. 23. CIE Standard, Lighting of indoor work places, CIE S008/E-2001, 2001. 24. Fleischer S., Krueger H., Schierz C. Effect of brightness distribution and light colours on office staff // The 9th European Lighting Conference Proceeding Book of Lux Europa 2001, Reykjavik, 2001, pp. 77-80. 25. CEN/TR16791:2017/E Quantifying Irradiance for Eye-Mediated Non-Image-Forming Effects of Light in Humans. 26. Koga Y., Yamakawa M. Potential Non-ImageForming Visual Effects of Violet-LED and Blue-LED White Light Sources // Proceeding Book of BalkanLight, 2018, pp. 17-21.
Keywords
Recommended articles