Content
Number of images - 5
Tables and charts - 7
Simulation And Design Study For Interior Zone Luminance In Tunnel Lighting. L&E 27 (2) 2019

Light & Engineering 27 (2)

Volume 27
Date of publication 04/22/2019

PDF

Simulation And Design Study For Interior Zone Luminance In Tunnel Lighting. L&E 27 (2) 2019
Articles authors:
Mehmet Sait Cengiz

Mehmet Sait Cengiz, Ph.D. He works in the field of applied lighting technologies and architectural illumination

Abstract:
An optimal solution for tunnel lighting designs was determined using a computer software. The road tunnel under construction 14481 m in length was selected in order to get an optimal design solution for tunnel lighting.The lighting, luminaries, and road parameters were changed and the resulting scenarios were examined in a simulation environment. The proposed approach can be applied for the illumination of interior zones in tunnels of 10 km or longer with significant reduction in energy consumption. The optimal luminance values that affect vision comfort in the tunnel were calculated in a simulation environment. As a result, the most economic lighting system and luminaries were chosen among solutions conforming to technical standards for luminance values.
References:
1. International Committer On Illumination-CIE-88, Guide for the Lighting of Road Tunnels and Underpasses, 1990.
2. CIE Technical ReportЦ88Ц2004. Guide for the Lighting of Road Tunnels and Underpasses [R], 2004.
3. Ozkaya, M., Ayd?nlatma Teknigi, Birsen Yay?nevi, Istanbul, 1994, 91.
4. Laurentin, C., Berruto, V., Fontynont, M. Effect of thermal conditions and light source type on visual comfort appraisal. Lighting Research & Technol., 2000. V32, #4, pp. 223-233.
5. CIE 140, International Commission on Illumination, Road Lighting Calculations, Vienna-Austria, 33 (2000).
6. CIE 61. Tunnel entrance lighting: a survey of fundamentals for determining the luminance in the threshold zone (E), 1984.
7. Veitch, J., Lighting and Health: issues for consideration, Light & Engineering, 2005, V13, #4, pp. 6Ц13.
8. Fuller, S., Carrasco, M., Exogenous attention and colour perception: performance and appearance saturation, Vision Research. 2006, 46, pp. 4032Ц4047.
9. Van Bommel, W., Van Den Beld, G., Van Ooyen M., Industrial light and productivity, Lighting & Engineering, 2003, V11, #1, pp. 14Ц21.
10. Iacomussi, P., Rossi, G., Soardo, P., Energy Saving and Environmental Compatibility in Road Lighting, Light & Engineering, 2012, V20, #4, pp. 55Ц63.
11. Pena-Garcia, A., Gil-Martin, L.M., Study of pergolas for energy savings in road tunnels. Comparison with tension structures. Tunnelling and Underground Space Technology, 2013, 35, 172Ц177.
12. Gil-Martin, L.M., Gomez-Guzman, A., Pena-Garcia, A., Use of diffusers materials to improve the homogeneity of sunlight under pergolas installed in road tunnels portals for energy savings. Tunnelling and Underground Space Technology, 2015, 48, 123Ц128.
13. DIN-67524, Beleuchtung von Strassentunnelen und Unterfuhrungen, 1972.
14. Onaygil, S., Guler, O., Erkin, E., Yol Ayd?nlatmalar?nda LED Kullan?m?, V. Ulusal Ayd?nlatma Sempozyumu ve Sergisi, 2009.
15. Cengiz C., Kaynakl? M., Gencer G., Eren M., Yapici I., Yildirim S., Cengiz MS., Selection Criteria and Economic Analysis of LEDs, Book of Abstracts, Imeset Int. Conf. Mult. Sci. Eng. Tech., October 27-29, 2017, Bitlis, Turkey.
16. UN Economic and Social Council, Economic Commission for Europe, Committee on Sustainable Energy, Steering Committee of the Energy Efficiency 21 Project, Final Report of Energy Efficiency Investment Project Development for Climate Change Mitigation, ECE/ENERGY/WP.4/ 2006/2, (21 March 2006).
17. Gencer G., Eren M., Yildirim S., Kaynakl? M., Palta O., Cengiz M.S., Cengiz C., Numerical Approach to City Road Lighting Standards, Book of Abstracts, Imeset Int. Conf. Mult. Sci. Eng. Tech., October 27-29, 2017, Bitlis, Turkey.
18. Y?ld?r?m S., Yap?c? I., Atic S., Eren M., Palta O., Cengiz C., Cengiz M.S., Yurci Y., Numerical Analysis of Productivity and Redemption Periods in LED Illimunation. Imeset Book of Abstracts, Int. Conf. Mult. Sci. Eng. Tech., , 12-14 July 2017, Baku.
19. CIE 115, International Commission on Illumination, Recommendations far the Lighting of Roads for Motor and Pedestrian Traffic, Vienna-Austria, 1995, 25.
20. Onaygil S., TEDAS Genel Mudurlugu Meslek Ici Egitim Semineri, TEDAS Bas?mevi, Ankara, 2007, 1-70.
21. Onaygil S., 2007. TEDAS Genel Mudurlugu Meslek Ici Egitim Semineri-Golbas? Egitim Tesisleri, Yol aydnlatma Semineri 23-24 Ocak 2007.
22. Cengiz MS., & Cengiz C., Numerical Analysis and An Application Study On Maintenance Factor In Tunnel Lighting, Journal of Engineering and Technological Sciences.(In press)
23. Onaygil, S., Yol ayd?nlatma projelerinde yol s?n?f?n?n belirlemesinin onemi, Kaynak Elektrik Dergisi, 1998, #12, 125-132.
24. Onaygil, S., УDetermining the Luminance of the Threshold Zone in Tunnel LightingФ, Ph. D. Thesis, Istanbul Technical University, 1990.